Дифференциальный автоматический выключатель Acti9 iDPN Vigi C 40A 4.5 kA
- Намуд: Калидаки автоматикӣ
Main
range
Acti 9
product name
Acti9 iDPN Vigi
product or component type
Residual current breaker with overcurrent protection (RCBO)
device short name
IDPNa Vigi
device application
Distribution
poles description
1P + N
number of protected poles
1
neutral position
Left
[In] rated current
32 A
network type
AC
trip unit technology
Thermal-magnetic
curve code
C
earth-leakage sensitivity
30 mA
earth-leakage protection time delay
Instantaneous
earth-leakage protection class
Type AC
breaking capacity
4500 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
suitability for isolation
Yes conforming to EN/IEC 60947-2
Complementary
device location in system
Outgoer
network frequency
50 Hz
[Ue] rated operational voltage
220...240 V AC 50 Hz
magnetic tripping limit
5...10 x In
residual current tripping technology
Voltage independent
[Ics] rated service breaking capacity
4500 A 100 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
rated breaking and making capacity
Idm 4500 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
limitation class
3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage
400 V AC 50 Hz
[Uimp] rated impulse withstand voltage
4 kV
contact position indicator
Yes
control type
Toggle
local signalling
ON, OFF, fault trip
mounting mode
Clip-on
mounting support
DIN rail
comb busbar and distribution block compatibility
Top or bottom: YES
9 mm pitches
4
height
85 mm
width
36 mm
depth
73 mm